Lifebreath 2500EFD Benutzerhandbuch

Seite von 20
8
Off
10
20
30
40
50
60
  DEHUMID
ISTAT
Optional Remote Controls
ON
OFF
HIGH
LOW
Supplied 
and Installed 
by Contractor
Dehum
idistat 
Setting
 Relativ
e to 
Outside
 Condit
ions
WINTER
:
Set deh
umidist
at 
betwee
n 30% t
o 40%.
If home
 is too d
ry, 
adjust t
o highe
r settin
g. 
If home
 is too h
umid,
adjust t
o lower
 setting
.
SUMME
R:
Set deh
umidist
at 
to OFF.
User Adjustable Defrost
DEHUMIDISTAT VENTILATION CONTROL*
LOCATION: Spa or pool area, anywhere that humidity 
is a concern. (connect 1/unit only)
• Ventilation control turns HRV system OFF and ON.
• Dehumidistat increases ventilation when required
• High speed override switch
Red - common / Black - hi/low / Orange - on/off
PART NO. 99-116 c/w 3 wire cable 60' (18m)
REMOTE DEHUMIDISTAT 
LOCATION: 
Spa or pool area, anywhere that humidity 
is a concern. 
• Provides high speed ventilation when humidity level
exceeds selected setting.
PART NO. 99-130
CRANK TIMER  
• 
Provides high speed ventilation as required.
Crank Timer - 60 minute
PART NO. 99-101
ON/OFF
HIGH/LOW
COMMON
I
I
I
I
I
I
I
I
I
I
I
I
I
I
II
II
II
II
II
II
II
II
II
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
ON
OFF
hrs
0
0.2
0.4
0.6
0.8
1.0
Factory pre-set dial positions
DO NOT ADJUST
Defrost timer device
(see wiring diagram 
for location)
Yellow (outer dial)
adjusts length of time
between defrost cycles
(OFF cycle)
Orange (center dial)
adjusts time spent in 
defrost mode
(ON cycle)
Orange 
Yellow
ON  
          OFF
OPERATION
Once the snap disk senses temperatures below 
-3˚C (27˚F), it will activate the defrost mode,
which begins with the Defrost OFF cycle, and
then continues into the Defrost ON cycle.
Factory pre-set defrost 
cycle and time are:
DEFROST ON
=.15 HR. (10 mins)
DEFROST OFF
=.50 HR. (30 mins)
32ºF (0ºC)
No defrost required
13ºF (-11ºC)
10 mins. defrost ON - 30 mins. defrost OFF
-40ºF (-40ºC)
15 mins. defrost ON - 30 mins. defrost OFF
EXAMPLES OF DEFROST CYCLES