B. Maintenance
The maintenance schedule below is a guideline. More frequent maintenance may be 
required depending on water quality, the icemaker's environment, and local sanitation 
regulations.
 WARNING
1. Only qualified service technicians should service this icemaker.
2. Move the control switch and the power switch to the "OFF" position and turn
off the power supply before servicing. Lockout/Tagout to prevent the power 
supply from being turned back on inadvertently.
Maintenance Schedule
Frequency Area
Task
Every 2 
Weeks
Air Filters
Inspect. Wash with warm water and neutral cleaner if dirty. 
Monthly
External Water 
Filters
Check for proper pressure and change if necessary.
Icemaker Exterior
Wipe down with a clean, soft cloth. Use a damp cloth containing a neutral 
cleaner to wipe off oil or dirt build up. Clean any chlorine staining (rust 
colored spots) using a non-abrasive cleaner like Zud or Bon Ami.
Every 6 
Months
Icemaker and 
Storage Bin
Clean and sanitize per the cleaning and sanitizing instructions provided in 
this manual.
Evaporator 
Condensate Drain 
Pan and Gear 
Motor Drain Pan
Wipe down with a clean cloth and warm water. Slowly pour one cup of 
sanitizing solution (prepare as outlined in the sanitizing instructions in 
this manual) into the evaporator condensate drain pan. Be careful not to 
overflow the pan. This solution will flow down to the gear motor drain pan 
and out the drain line to sanitize these areas. Repeat with a cup of clean 
water to rinse.
Icemaker, Storage 
Bin, and Drip Tray 
Drains
Check to make sure they are clear.
Yearly
Inlet Water Valve 
and Drain Valve
Close the icemaker water supply line shut-off valve and drain the water 
system. Clean the inlet water valve screen and clean and inspect the drain 
valve.
Water Hoses
Inspect the water hoses and clean/replace if necessary.
Condenser
Inspect. Clean if necessary by using a brush or vacuum cleaner.
Icemaker
Inspect for oil spots, loose components, fasteners, and wires.
Upper Bearing 
(extruding head)
Check for wear using .02" round stock or pin gauge. Replace both upper
bearing and lower bearing if wear exceeds factory recommendations. See 
the Service Manual for details.
After 
3 Years, 
then Yearly
Upper Bearing 
(extruding head); 
Lower Bearing 
and O-Ring 
(lower housing); 
Mechanical 
Seal; Evaporator 
Cylinder; Auger
Inspect. Replace both upper bearing and lower bearing if wear exceeds 
factory recommendations. Replace the mechanical seal if the seal's contact 