U-Line BI95 Benutzung Und Pflege

Seite von 20
12
BI95, BI98, SP18
Ice Cube Thickness Adjustment
Interval - As Required
The ice cube size may be adjusted by changing the 
amount of water injected into the ice maker assembly as 
follows:
Figure 12
1. Remove the ice maker assembly cover (Figure 12).
Figure 13
2. Locate the adjusting screw on the ice maker assembly 
control box. The adjusting screw is just below the minus 
(-) and plus (+) signs on the control box (Figure 13).
NOTE: Make adjustments in small increments. Too 
large of an adjustment could cause the unit to 
malfunction.
3. Turn the adjusting screw toward the minus (-) sign 
(clockwise) for smaller cubes or toward the plus (+) sign 
(counterclockwise) for larger cubes.
4. Install the ice maker assembly cover.
IMPORTANT
IMPORTANT
Use only genuine U-Line replacement parts. U-Line 
ice maker parts are not the same as standard FSP 
Whirlpool parts. Using non U-Line parts can reduce 
ice rate, cause water to overflow from ice maker 
mold, damage the unit and may void the warranty.
Leveling
IMPORTANT
IMPORTANT
It is extremely important that the unit sits on a 
level surface, as it does not have feet levelers. If it 
is not level, the ice mold will not fill evenly.
Use a level to check the levelness of the unit from front to 
back and from side to side. Level should be placed along 
top edge and side edge as shown (Figure 15, 1).
Figure 14
ULIN_0237_A
ULIN_0056_A
1
ULIN_0309_A