Cornelius CCM0530 Benutzerhandbuch

Seite von 129
 
 
 Water System 
Page D2 
 
Water Distribution Disassembly 
Remove 2 screws holding the distribution tube to the evaporator spillway.  Remove the clamp 
holding the water tube to the distribution tube.  Twist the end caps of the distribution tube 
counterclockwise and pull to remove the inner tube halves from the outer tube.  To reassemble, 
push the inner tube halves into the outer tube with the holes facing the same direction.  Make sure 
the inner tube halves seat together completely.  Twist the end caps clockwise ½ turn to lock the 
inner tubes in place.  The holes in the tubes will now be facing in the opposite directions. 
 
Important! For proper water flow over the evaporator, the inner tube holes must face up. 
 
 
 
 
 
 
 
 
 
 
 
Turn counterclockwise to remove