Installation Instructions
Clamps
Bare metal
Insulating device
4 AWG wire
(minimum)
three Wire Connection with External Ground
Conduit to 
oven
Incoming 
Power
Wire Nut,
4 Places
Junction Box
Separate 10 AWG 
Wire Minimum
Clamp wire tightly 
to pipe
Connecting to a Three Wire Electrical 
System with External Ground - Where Local 
Codes Permit
 WARNING
Do not ground the appliance to a gas supply pipe or 
hot water pipe.
If connecting the ground wire to a grounded cold water 
pipe, connect using a separate copper grounding 
wire (No. 10 minimum) and a clamp with an external 
grounding screw. The grounded cold water pipe must 
have metal continuity to electrical ground and must not 
be interrupted by insulating materials. Any insulating 
materials must be jumped, with a minimum, 4 AWG 
wire to establish continuity to ground.
 NOtE
If the junction box has been properly grounded by a 
licensed electrician, the green (ground) wire from the 
appliance conduit may be connected to the junction box 
using a loop terminal.
to connect the green appliance conduit wire to a 
grounded cold water pipe:
Separate the wires coming out of the 
1. 
appliance conduit.
Connect the white wire
2. 
 from the appliance conduit to the 
white (neutral) supply wire in the junction box.
Connect the black wire from the appliance conduit to the 
3. 
black (L1) supply wire in the junction box.
Connect the red wire from the 
4. 
appliance conduit to the 
red (L2) supply wire in the junction box.
Connect the green wire from the 
5. 
appliance conduit to a 
grounded cold water pipe as shown. Jumper any insu-
lating materials as shown above with a length of No. 4 
copper wire. Securely clamp the wire to bare metal at 
both ends.
Insulated Pipe Jumper