Frigidaire FGEW3045K F/W/B Benutzerhandbuch

Seite von 9
Specifications  
subject to change.
30" Electric Single Wall Oven Specifications
 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 
AC only electrical supply with ground required on separate circuit 
fused on both sides of line.
 For detailed electrical requirements, refer to model-specific product 
page and installation guide on web.
 To support Wall Oven when using in combination with Warmer 
Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base, 
capable of supporting 200 Lbs. Do NOT use full base, since planks 
are necessary to allow for proper air displacement.
30" Warmer Drawer Specifications
• Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 0.5 kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
• Amps @ 120V = 3.8 Amps
• Full base of solid plywood or similar material required, capable of
supporting 100 Lbs. 
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
30" Combination Installation Specifications
 Always consult local and national electric codes.  
(Refer to product-specific electrical specifications on this page.)
 Minimum 23-5/8" deep cutout dimension is critical for proper 
combination installation, to ensure that each built-in product’s 
faceplate will fit flush against cabinet front.
 Bases must be level and cabinet front must be square.
 Minimum 4-1/2" required distance from bottom of Warmer Drawer 
cutout to floor.
 Respect critical dimensions as noted for proper installation of  
built-In products.
 Minimum 21" clearance needed for Wall Oven door depth when open.
30" Built-In Microwave Specifications
 For built-in installation, microwave MUST be installed with optional 
30" Trim Kit which includes Bottom Duct Assembly – shipped in 
separate box, ordered by individual part number. 
 Voltage Rating – 120V / 60 Hz / 15 or 20 Amps
 Connected Load (kW Rating) @ 120 Volts = 1.7 kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
 Amps @ 120 Volts = 14.3 Amps
 Full oven base of solid plywood or similar material required, capable 
of supporting 100 Lbs.
 Minimum 2-7/8" clearance required from bottom of Built-In Microwave 
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap 
between both product faceplates.  
Frigidaire 30" Combination Installation –
24" Built-In Microwave (with 30" Trim Kit)
Electric Single Wall Oven
Warmer Drawer
30" Combination Installation