Equator SB 818 Benutzerhandbuch

Seite von 13
Defective seal on plunger. 
Over filling container. 
Replace plunger. 
◇ Follow instructions in owner’s 
manual. 
Noisy pump assembly. 
Impellers not properly shimmed or 
rubbing. 
 
 
 
Pump parts not properly installed. 
Debris in bottom of tub sump area.
Defective motor bearings. 
◇ Use shim gauge furnished in 
impeller and seal kit, when seals 
are properly shimmed the 
impellers will be in correct 
operating position. 
Inspect and correct. 
Clean out sump area. 
Replace motor. 
Dishwasher continues to fill 
or continues to fill even 
though in case of there is no 
voltage to fill valve. 
● Something (dirt or foreign 
material) under diaphragm in water 
inlet valve. 
Defective water inlet fill valve. 
◇ Clean water inlet valve or 
replace. 
 
Replace water inlet valve. 
Detergent left in dispenser. 
Detergent cup held or blocked by 
large dishes. 
● Dispenser wet when detergent  
was added. 
On proper loading dishes. 
 
Instructs customer/user. 
Softener leaking 
Softener broken. 
Softener nut loosen. 
Replace softener. 
Screw down softener cap. 
Leaking form air inlet. 
Air inlet nut loose. 
Air inlet install up side down. 
Screw down air inlet nut. 
Reinstall air inlet properly. 
Window Display “E1” 
Inlet Valve Damaged. 
Inlet Valve Disconnected.
 
Replace Inlet Valve. 
Reconnected Line.
 
Window Display “E2”
 
Pressure Switch Damaged.
 
Replace Pressure Switch.
 
Window Display “E3”
 
Heating Element (open). 
Power Supply To heating Element 
Cutting.
 
Replace. 
Reconnect  Line.
 
Window Display “E4”
 
Float Switch Act.
 
Take Remove The Rubber Cap 
Let Water Pour Out.
 
Window Display “E5”
 
Thermostat Sensor Damaged.
 
Replace sensor(See figure8).
 
 
 13