Liebherr EWTN Benutzerhandbuch

Seite von 35
A delight in freshness
WFI1051 / EWTN 2956
8
I
NTEGRATING
 C
ABINETRY
Figure 5
IMPORTANT
If you are replacing the factory air vents with 
an overlay, DO NOT restrict the air flow. The air 
flow must be the same or greater than the fac-
tory air vents of 31 square inches (200 cm²).
The door handles must be installed before the 
screw covers are installed. If you fail to install 
the handles before the screw covers, you can 
damage the covers. The screw covers are 
taped to the unit doors during shipping. Use 
care when removing covers.
The door panel weight must not exceed 
25 lb (11,3 kg).
Framed Panels
 - Figure 5
If the thickness of the custom panels is less than 
1/4" (6.4 mm), they must be backed up with a sheet 
of shim material to build the total thickness to 1/4" 
(6.4 mm). If the panel is thicker than 1/4" (6.4 mm), 
an edge must be routed around the panel to 
ensure a proper fit.
1/4"
(6.4 mm)
22-9/16" (573 mm)
32-37/64" (828 mm)
37-9/32" (947 mm)
1/4" (6.4 mm)
1/4"
(6.4 mm)
1/4" (6.4 mm)
=
=
Window cutout
max. 17-1/2" (445 mm)
max.
25-1/2" (648 mm)
3-1/16"
(78 mm)