Jenn-Air W10197058B Benutzerhandbuch

Seite von 24
9
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m). 
For elevations above 2,000 ft (609.6 m), ratings should be reduced 
at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not 
applicable for Canada). 
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure shown on 
the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing of 
that system at test pressures in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping system 
by closing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal to 
or less than ½ psi (3.5 kPa).
INSTALLATION INSTRUCTIONS
Install Cooktop
Decide on the final location for the cooktop.
1. Open carton as instructed on product packaging.
2. Remove shipping materials and tape from cooktop.
3. Remove the removable grease filter by lifting the filter out.
4. For island or peninsula installations, go to the “Rotate Blower 
- Optional” section.
5. Using 2 or more people, remove the cooktop from the carton.
REMEMBER: An undercounter built-in oven cannot be 
installed under this cooktop.
6. Place cooktop right side up into the cutout.
NOTE: Make sure that the front edge of the cooktop is parallel 
to the front edge of the countertop. If repositioning is needed, 
lift entire cooktop up from the cutout to avoid scratching the 
countertop.
7. Connect blower exhaust scroll to ducting.
8. Use vent clamps to secure the ducting to the blower exhaust 
scroll.
9. Reinstall grease filter.
10. Reinstall vent grille.
Rotate Blower - Optional
IMPORTANT: The following additional steps must be performed if 
the product is being installed in peninsula or island cabinetry.
The blower exhaust scroll is shipped from the factory set to 
exhaust straight out the back of the cabinet through an exterior 
wall.
To rotate blower:
1. Locate the 4 plastic plugs in the plenum bypass.
2. Use the pliers to remove the plastic plugs. 
IMPORTANT: Do not throw away the plastic plugs. The plastic 
plugs must be reinstalled after the blower exhaust scroll has 
been rotated.
A. Removable grease filter
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
A
A. Blower exhaust scroll
B. Plenum
C. Blower motor
D. Top label
E. 10-32 machine nuts (4)
F. Motor mounting plate
A. Blower motor
B. Exhaust scroll
C. Plenum
D. Blower bypass
E. Plastic plugs (4)
D
E
C
A
E
F
B
A
B
C
D
E