 | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 2. Trunk Communication Board (TCB4)
 
2.4  
 
S9  DIP-Switch settings
 
See 
fig. 2-1
 for location, and 
Table 2.1
 for functionality of the DIP-switches.
 
2.5  Jumper settings
 
See 
fig. 2-1
 for location, and  
Table 2-2
 for functionality of the jumpers.
 
Table 2.1 :  S9 DIP-switch settings
 
TCB4
 
SW 1
ON*
OFF
Chairman priority  tone ON 
 
(default).
 
Chairman priority  tone OFF
SW 2
ON
OFF*
Audio ‘Mix-Minus’ mode activated in combination with SW3 = 
OFF
Normal Operation 
 
(default).
 
SW 3
ON
OFF*
Audio ‘Insertion’ mode activated in combination with SW2 = 
OFF
Normal Operation 
 
(default).
 
SW 4
OFF
Reserved 
 
(IMPORTANT: 
 
must not be changed)
SW 5
OFF
Reserved 
 
(IMPORTANT:
 
 must not be changed)
SW 6
ON
OFF*
Active microphones and request will be permanently switched 
off if the priority function of the chairman unit is used.
Active microphones will be  switched off  temporarily if the prior-
ity function of the chairman unit is used 
 
(default).
 
SW 7
OFF
Reserved 
 
(IMPORTANT: 
 
must not be changed)
SW 8
ON
OFF*
Switching on the CCU will activate the BOOT software, this 
makes a new download possible. All memory settings will be 
erased and returns to the default settings. The unit addresses 
will not be erased.
Normal operation 
 
(default).
 
* = default setting
 
DIP switch S9 (default settings)
 
 
For location
 
see
 fig.. 2-1 .
S9
ON
1 2 3 4 5 6 7 8
switches 4, 5 and 7 are ‘RESERVED’
Must NOT be changed
 
 
Table 2.2 : Jumper settings
 
TCB4
Default
Function
 
X13
1 & 2
Jumpered to provide SRAM Battery back-up
Open when removing back-up battery. (Position 2 & 3)
X14
1 & 2
Watchdog active
Open for service purposes. (Position 2 & 3)