SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 • September 2008
In case that the OpenBoot PROM version of the XSB to which the resource of the 
target CMU has been assigned is not displayed as 02.03.0000, contact a  service 
engineer.
14. Turn off the target domain. 
15. Mount the CPU module (CPUM) on the CMU for add-on. 
For the procedure, see the description about the CPU module installation in Section 
6.4.1, "Replacing a CPU module" in the SPARC Enterprise M8000/M9000 Servers 
Service Manual
16. Mount the CMU, described in step 15, on the server. . 
a. Executing the addfru(8) command and select “CMU/IOU” from the maintenance 
menu.
b. Perform the operation according to the instructions displayed in the 
maintenance menu, referring to “6.2 Active Replacement and Hot Replacement” 
in SPARC Enterprise M8000/M9000 Servers Service Manual
.
Note – 
Do not fail to execute the diagnosis of newly mounted CMU in the maintenance 
menu of addfru(8) command.
17. Confirm that the mounted CPU module has been recognized by the server, and the 
error indicator asterisk (*) is not displayed. 
18. Confirm no abnormality occurred by using showlogs error -v and 
showstatus
(8) commands.
If you encounter any hardware abnormality of the XSCF contact a  service engineer.
19. Move the key position on the operator panel from Service to Locked.
20. Sets the following for the CMU.
Set up XSB.
Set up the LSB.
Add the XSB to the domain. 
XSCF> poweroff -d 
domain_id
XSCF> addfru
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus