Tools Required
        Anti-static
wrist strap
     Phillips*
screwdriver
Caution
 
Observe normal ESD
 
[Electrostatic Discharge]
 
procedures during system 
integration to avoid possible 
damage to compute module and/or 
other components.
Warning
 
Installation and service of 
 
this product to be performed 
 
only by qualified service 
personnel to avoid risk of injury from 
electrical shock or energy hazard.
Warning
 
Read all caution and safety 
 
statements in this document 
 
before performing any of the 
instructions.  Also see the Intel
®
 
Server Board and Server Chassis 
Safety Information document at:
http://support.intel.com/support/
motherboards/server/sb/cs-010770
.htm
 
for complete safety information.
4
Install System in Rack (Optional)
Storage Controller
A
B
Main Cooling Module
A
B
Power Supply Module
A
B
Ethernet Switch Module
A
B
Management Module
A
B
Chassis Back
I/O Cooling Module
A
B
Chassis Front
4(b)  Finishing Up
THREE PEOPLE ARE REQUIRED TO LIFT THE 
SYSTEM. If handles are present, remove the rear 
handles prior to setting system onto slide rails. 
Remove the front handles prior to sliding system 
all the way into rail assembly.
Secure system to rack per rail kit installation 
instructions.
Re-install all power supply modules, cooling modules, 
the storage controller, the management module and the
Ethernet switch module. See the Intel® Modular Server 
System MFSYS25 User Guide  
for complete instructions on installing modules.
To re-install a power supply or cooling module:
     ■
  Slide module into appropriate module 
 
bay until retention latch engages.
To re-install a management module, storage controller
or Ethernet switch module:
     ■
  Ensure retention lever is released and 
 
rotated out and away from module.
     ■
  Slide module into appropriate module 
 
bay until bottom of retention lever 
 
engages with bay.
     ■
  Rotate retention lever in toward module 
 
until it latches.
4(a)  Preparation
Prepare rail system for rack mounting. Refer to the 
Rail Kit Install Guide that is included with your rail 
kit for instructions on assembling the kit.
Remove all modules from the Intel® Modular
Server System prior to lifting system into rack. This 
includes all cooling modules, all power supply
modules, the management module, the Ethernet 
switch module, and the storage controller. Refer to 
adjacent illustrations for module location. See the 
Intel® Modular Server System MFSYS25 User 
Guide for complete instructions on removing modules.
To remove a power supply or cooling module:
 
Press retention latch to the left to
 
release module from module bay.
 
Slide module out of module bay.
To remove the management module, storage controller
or Ethernet switch module:
 
Press retention latch to the left to release
 
module from module bay.
 
Rotate retention lever out and away from
 
module.
 
Slide module out of module bay.
A
B
A
B
C
Three people ARE REQUIRED to lift the empty 
system into the rack assembly. DO NOT lift 
system while fully loaded.
Rear handles MUST BE removed prior to setting
system on rack rails. The profile of the handles
interferes with rack rails.
Front handles MUST BE removed prior to sliding
system all the way into rail assembly.
3
Install Pedestal
Feet (Optional)
Remove temporary handles if 
present.
Lay chassis down horizontally.
Remove pedestal feet from strip
of sticky paper.
Affix one foot to each of the six
indent locations on the bottom
side of the chassis.
A
B
C
D
2
Install Temporary Handles (Optional)
A
A
A
A
B
B
Insert handle tabs into chassis slots.
Tighten captive screws.
A
NOTE:  Handles are provided as 
temporary devices to assist in
removing system from packaging
and for initial configuration. 
DO NOT lift system
by power supply or
cooling module
handles. 
1
Unpackaging
System
As packaged, the system 
weighs 100 lbs. Install 
temporary handles (see 
Step 2) before lifting system 
from shipping box.
Do not lift system from 
packaging by power supply
or cooling module handles.
A minimum of three people 
are required to lift system as
packaged.
Temporary handles will need
to be removed if system is
to be used in the pedestal or
rackmount configurations. 
Package Contents
 
 
Intel® Modular Server System MFSYS25
■  
Intel® Gigabit Ethernet Switch AXXSW1GB 
    plus one filler blank
■  
Intel® Storage Controller plus one filler blank
■  
Intel® Management Module
   
■  
2 power supply modules
■  
2 power supply blanks
■  
1 I/O cooling module
■  
2 main cooling modules
■ 
   5 compute module blanks
■  
2.5-inch SAS shared hard drive bay
■  
14 hard drive carriers
■  
Resource CD
■  
This document
■  
Attention Document
   Rail kit
   6 pedestal feet
If you are not familiar with ESD (Electrostatic Discharge) procedures 
used during system integration, please see the Intel
®
 Modular Server 
System MFSYS25 User Guide, available at 
http://support.intel.com/support/motherboards/server/MFSYS25
Read all cautions and warnings before starting your server system integration.
Thank you for buying an Intel
®
 Modular Server System.  
The following information will help you 
assemble your Intel
® 
Modular Server System MFSYS25
and install components. 
This guide and other supporting documents 
are located on the web at: 
http://support.intel.com/support/motherboards/server/MFSYS25
Intel
®
 Modular Server System
MFSYS25
Quick Start User's Guide