Canopy  T1/E1 Multiplexer 
 
 
 
 
 
 
September 2004 
 
 
 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
 
 
 
Page 45 of 73 
Action Steps 
Set timing mode  
NOTE: Timing mode applies to all four E1 lines. Loopback mode loops the T1/E1 
Tx clock to the T1/E1 Rx.  Recovered mode recovers the T1/E1 clock from the 
incoming T1/E1 over Ethernet bit stream (recovers the clock from the far end 
T1/E1). The default timing mode is Recovered. 
 
For master clock timing mode, enter  
set clock source loopback 
RESULT: The system responds 
Clock source is loopback 
 
For slave clock timing mode, enter  
set clock source recovered 
RESULT: The system responds 
Clock source is recovered 
 
Log off 
Enter lo
RESULT: The system responds goodbye. 
 
 end of procedure
2.5  CONFIGURATION PROCEDURES USING THE EMS 
2.5.1  Logging into the System 
Procedure 14: Logging in using the EMS 
If you are using the EMS to access the system, follow the steps below to log in: 
1.  Select the proper COM Port for your PC.   
NOTE: COM1 through COM4 are supported.    
2. Enter 
the 
User Name.   
NOTE: The default username is admin. This value cannot be changed.   
3. Enter 
the 
Password.   
NOTE: The default password is 123.  If the password has been changed, enter 
the correct password. 
4. Select 
the 
Login button to continue with the login.   
NOTE: If the login is unsuccessful, the system will generate a pop-up error 
window. You may return to the Login window to correct the data. 
 