Fujitsu FBR12 Benutzerhandbuch
(a)
Series Name
FBR12 : FBR12 Series
(b)
Enclosure & Coil Power
N
: Standard (plastic sealed type)
W
: High dielectric strength type (plastic sealed type)
H
: High sensitivity type
(c)
Coil Type
D
: DC coil
(d)
Nominal Voltage
Refer to the COIL DATA CHART
(e)
Contact Material
Nil
: Gold-overlay silver-nickel
–P
: Gold-overlay silver-palladium
(f)
Custom Designation
To be assigned custom specification
(g)
CSA Standard
–CSA
: UL114 + CSA recognized
–CSA
: UL1950 + CSA (under application)
Note: The designation name is stamped on the top of the relay case as follows:
(Example) Designation ordered: FBR12ND05
Stamp: 12ND05
■
FEATURES
●
Super miniature size: 0.2 inch
×
0.1 inch grid, 12 pin DIP
Up to 50% less volume and board area than previous
generation telecom relay.
generation telecom relay.
●
Slim type for high density mounting
●
Conforms to Bellcore TR-NWT-001089 and FCC Part 68
requirements
●
UL recognized and CSA certified
●
Low power consumption
●
Conforms to IEC 950 (W type only)
– 2.5 mm clearance and creepage between coil and contacts
–5000 V surge strength between coil and contacts (2x10
– 2.5 mm clearance and creepage between coil and contacts
–5000 V surge strength between coil and contacts (2x10
µ
s
surge wave)
–2000 Vrms dielectric strength between coil and contacts
–UL 1950 and IEC950 (approval in process)
–UL 1950 and IEC950 (approval in process)
FBR12 N
D
12
–P
–**
(–CSA)
[Example]
(a)
(b)
(c)
(d)
(e)
(f )
(g)
FBR12 SERIES
MINIATURE RELAY
2 POLES—1 to 2 A (FOR SIGNAL SWITCHING)
■
ORDERING INFORMATION
1
■
SAFETY STANDARD AND FILE NUMBERS
Nominal coil voltage
Contact rating
0.5 A 125 VDC resistive
3 to 24 VDC
2 A 30 VDC resistive
0.3 A 110 VAC
0.3 A 110 VAC
resistive
UL508, 1950, 114 (File No. E63615)
C22.2 No. 0, No. 14 (File No. LR40304 or LR64026)
C22.2 No. 0, No. 14 (File No. LR40304 or LR64026)
NOT FOR NEW
DESIGN
FBR12 SERIES TO
BE DISCONTINIED