Switch Installation – Multiple units – “Split-BUS” topology 
A “Split Bus” configuration is usually used when the users are 
connected to the first and last UltraMatrix switch and need access 
to all connected CPUs. This topology can only be done using the 4xE 
model with two expansion cards installed in each switch. 
 
  
 
Figure 6. Split-Bus configuration 
The Units in Figure 6 must be 4xE models with 2 expansion cards. 
 
Steps: 
1.  Verify that power is “OFF” on all UltraMatrix switches. 
2.  Configure the “Starting computer” number for all the UltraMatrix 
switches, starting with Unit #2 by: (Unit #1 default = 1) 
a.  Connect a KVM station to Unit #2’s KVM #1 connector using 
the appropriate KVM adapter cable.  
b.  Apply power to the KVM monitor and to UltraMatrix #2. 
c.  When the internal diagnostic completes, press and release the 
left control [Ctrl] key, then the F12 key to display the “Main 
menu”. 
d.  Select “System” and press [Enter].   
 