Appendix D. Status Connect / Failure Reason Summary 
 
Reason 
Description 
Action 
Can’t Find 
Computer 
Unable to communicate 
to the computer that’s 
being connected to. 
Change invalid starting 
computer number, 
incorrect expansion 
cable placement or 
power up expansion 
Unit. 
Computer is 
Private 
Another user is 
connected in private 
mode. 
Wait for the private 
user to disconnect and 
retry the connect 
request. 
No Response 
Communications error. 
Cycle power to the 
UltraMatrix switch 
where the CPU is 
attached. 
Not in Access 
Group 
A user profile specifies a 
group without access to 
this computer. 
Connect to another 
computer, use another 
group, or include the 
computer in the user’s 
group. 
Out of Range 
Attempt to connect to a 
computer with a number 
greater than the 
maximum computer 
parameter. 
Connect to a computer 
with a lower number 
than the maximum or 
reconfigure all Units 
with a higher maximum 
computer number. 
Queue Full 
The Maximum number of 
KVM stations is already 
connected to the CPU 
Wait until a user 
disconnects from the 
CPU 
Unknown 
Computer 
Attempt to connect to a 
computer number greater 
than the Maximum 
computer number 
Change request to 
another computer 
number. 
 
Unknown Reason Internal error occurred 
during 
connect/disconnect. 
Cycle power on all 