Installation 
(continued)
4.  Install feed circuit wires
 
Install the feed wires from the shore power inlet or other AC source,  
 
referring to the wire sizing chart to select the correct wire size. Connect  
 
the black AC hot, white AC neutral and green AC safety ground as  
 
shown in the illustration.
 
If the feed wires are from the shore power inlet or the electrical    
 
attachment point of a permanently installed shore power cord and the  
 
inlet or attachment point is more then 10 feet from this panel, an    
 
additional fuses or circuit breakers must be installed within 10 feet of  
 
the shore power inlet. The measurement is made along the  
 
 conductors.
5.  Installation of Backlight System
 
The backlight board is a DC device.  When installing it in an AC panel  
 
both wire leads must be connected to an appropriate DC source and  
 ground.
 
Connect the yellow negative wire to a DC ground.  Connect the red  
 
positive wire to any DC positive supply, usually a switch that controls  
 
the vessel’s other nighttime illumination.
6.  Apply branch circuit labels and mount panel
Apply a label for each of the branch circuits from the 30 basic labels 
provided. If the appropriate label is not included, the Extended Label 
Set of 120 labels may be ordered from your marine supplier (PN 8067). 
Individual labels are also available from Blue Sea Systems for specifi c 
applications. Refer to the label order form for a complete listing of 
individual labels.
Fasten the panel to the mounting surface using the panel mounting 
screws supplied with the panel.
7. Testing
 @
  Connect the vessel’s shore power and verify the Reverse Polarity  
 
 
light is not illuminated. If the red Reverse Polarity light is on then  
 
 
either the hot and ground or the hot and neutral wires have been  
 
 
crossed. Starting at the panel, trace the connections  back as far  
 
 
as necessary to locate the error.
 @
  Using a multimeter where the power source is connected to the  
  panel 
verify:
 
 
PN 8618 / PN 8620 - 120 Volt AC
 
 
 
a. 
120 volts between hot and neutral
 
 
 
 
(nominal, this may vary depending on source voltage) 
 
 
 
b. 
120 volts between hot and ground.
 
 
 
c. 
0 volts between neutral and ground.
 
 
PN 8619 / PN 8621 - 230 Volt AC
 
 
 
a.     230 volts between hot and neutral
 
 
 
 
(nominal, this may vary depending on source voltage) 
 
 
 
b. 
230 volts between hot and ground.
 
 
 
c. 
0 volts between neutral and ground.
 @
  Turn on each branch circuit to verify power to each circuit.
 @
  Review the meter installation and operation manual. Reference  
 
 
the Theory of Operation, Use, Installation Overview and  
 
 
 
operations sections. Verify meter functions.
8.  Optional Branch LED’s
 
This Panel is supplied with LED’s pre-installed in all optional branch  
 
positions. For future expansion of the panel remove the hot leg of the  
 
LED from the AC Neutral Bus and connect it to the Load side of the  
 
branch circuit breaker.
Note
All Blue Sea Systems’ AC electrical distribution panels are furnished 
with 15 amp or 8 amp circuit breakers for branch circuits. 15 amp 
circuit breakers are used in all 120 volt panels and 8 amp circuit 
breakers are used in all 230 volt panels. These ratings were selected 
to minimize the need for removing the panel’s circuit breakers and 
reinstalling different size circuit breakers. It is very rare to have more 
than this amount of current fl owing in any one circuit. Therefore, these 
circuit breakers will satisfy the vast majority of marine circuit protection 
situations.
The Purpose of a Panel
There are six purposes of a marine electrical panel:
• Power distribution
•  Circuit (wire) protection
•  Circuit ON/OFF switching
•  Reverse Polarity Indication
•  Metering of voltage and amperage  (In panels with meters)
•  Condition Indication  (circuit energized)
Useful Reference Books
Calder, Nigel, 1996: Boatowner’s Mechanical and Electrical Manual,
  2nd edition, Blue Ridge Summit, PA: TAB Books, Inc.
Wing, Charlie, 1993: Boatowner’s Illustrated Handbook of Wiring
  Blue Ridge Summit, PA: TAB Books, Inc.
Wiring Diagram
AC Main Power Distribution Panel 
with AC Digital Multimeter
(PN 8620 shown for reference)