Routine Maintenance
Clean the Printhead and Platen Roller
110
11342L-001 Rev. A
105SL User Guide
6/30/06
3.
. Using the swab from the Preventive Maintenance Kit (part number 47362), 
wipe along the brown strip on the printhead assembly from end to end. In place of the 
Preventive Maintenance Kit, you may use a clean swab dipped in a solution of isopropyl 
alcohol (minimum 90%) and deionized water (maximum 10%). Allow the solvent to 
evaporate.
Figure 29 • Printhead and Platen Roller Cleaning
4.
While manually rotating the platen roller, clean it thoroughly with the swab. Allow the 
solvent to evaporate.
5.
Reload the media and the ribbon (if required).
1
Swab
2
Platen roller
3
Printhead print elements
4
Printhead-open lever
1
2
3
4