Avery 676 Benutzerhandbuch

Seite von 79
User Manual Model 676 LOKPRINT® 
Printer Unpacking / Installation  •
••
•  11 
Fuse Configuration 
The main fuse(s) on the AVERY DENNISON 676 LKP are located inside the AC 
power entry receptacle.  The entry has a fuse drawer that holds the fuse(s) and selects 
the appropriate line voltage.  If the number in the window DOES NOT match the AC 
line intended to be supplied to the printer, DO NOT plug the power cord in.  Re 
configure as follows: 
 
1) Using a flat blade screwdriver, open the AC entry by lifting the tab just above the 
voltage indicator window. 
WARNING: Attempting to open the AC entry with the AC power cord inserted into 
it will cause damage to the AC entry. 
2) Remove the red fuse drawer. 
3) Remove all fuses and the fuse jumper if it is present. 
4) Insert into the fuse drawer the correct number and style of fuses and fuse jumper 
for your application. 
 
Configuration Number One:  
Line voltage between the range of  
 
90 - 132VAC @ 50 - 60Hz 1 Ph 
 
 
1) Install one 921167 - 10.0A 250V Fast Acting 1/4 x 1 1/4" 
 
 
2) Install one Fuse Jumper 
 
 
 
See Figure FUSE1 
 
Configuration Number Two: 
Line voltage between the range of  
180 - 265VAC @ 50 - 60Hz 1 Ph 
 
 
1) Install two 921168 10.0A 250V Fast Acting 5 x 20MM 
NOTE: The fuse jumper must be removed to install both 5 x 
20mm fuses. 
The fuses must be between points A and B as shown not B and C. 
 
 
 
See Figure FUSE2 
 
FUSE 1  
 
 
 
 
 
FUSE 2 
Location of 115V Text
Location of 230V Text
Two 5 x 20MM Fuses One Each Side
One 1/4 x 1 1/4" Fuse Far Side
Location of 115V Text
Location of 230V Text
Fuse Jum per
5 x 20 m m  fuse
FRONT
FRONT
A
B
C
 
5) Reinsert the fuse drawer into the AC entry with the desired voltage up. 
6) Close the AC entry and verify the correct voltage is now visible.