Samsung BCD-1000 Benutzerhandbuch

Seite von 54
 
Rev. 1.00 
- 20 -
BCD-1000 Series 
English 
7. Switches 
 
7-1 Display Switch 
 
7-1-1 Feature : A Display Switch is located on the bottom of the display panel. 
 
7-1-2 Function : Turns the power supply on/off. 
 
 
7-2 DIP switches 
 
7-2-1 Feature : Two DIP switches are located on the back of the display panel. 
 
7-2-2 Functions : The DIP switch settings are read only when the power is turned on. 
Therefore, changing the settings while the power is on has no effect. 
 
7-2-3 DIP S/W #1 Function (RS-232 Serial Input Setting) 
 
No. 
Function 
Switch OFF 
Switch ON 
1 Default 
Setting 
DIP 
Switch 
Values EEP-ROM 
Data 
Leading 
N.C (No Connection)
Reserved for Future Using 
Reserved for Future Using 
Display Viewing Side
Customer Side 
Operator Side 
Self-test Execution 
Does not execute 
Executes 
5~8 Command 
Emulation
 
5 6 7 8
Command 
Emulation 
5 6 7 8
Command 
Emulation 
0 0 0 0
Samsung VFD 
1 0 0 0 NCR Real POS 
0 0 0 1 Epson ESC/POS 1 0 0 1
PD6000 
0 0 1 0
ADM787/788 1 0 1 0
ICD2002 
0 0 1 1
DSP800  1 0 1 1
Reserved 
0 1 0 0
AEDEX 1 1 0 0
Reserved 
0 1 0 1
UTC Standard 
1 1 0 1
Reserved 
0 1 1 0
UTC Enhance 
1 1 1 0
Reserved 
0 1 1 1
CD5220  1 1 1 1
Reserved 
 
(“0” : S/W OFF,    “1” : S/W ON) 
 
7-2-4 DIP S/W #2 Function (Command Emulation Mode and Self Test Setting) 
 
No. 
Function 
Switch OFF 
Switch ON 
Data Length 
8 bits 
7 bits 
Parity using 
Non parity 
Parity 
3 Parity 
Selection 
Odd 
Even 
4~6 
Baud-rate 
Selection 
 
4 5 6
Baud-rate 
4 5 6
Baud-rate 
0 0 0
9,600 bps 
1 0 0
115,200 bps 
0 0 0
4,800 bps 
1 0 1
  57,600 bps 
0 1 1
2,400 bps 
1 1 0
  38,400 bps 
0 1 0
1,200 bps 
1 1 1
  19,200 bps 
 
(“0” : S/W OFF,    “1” : S/W ON) 
7~8  N.C (No Connection)
Reserved for Future Using 
Reserved for Future Using