FARGO electronic C10 Benutzerhandbuch

Seite von 178
RESTRICTED USE ONLY 
 
Fargo Electronics, Inc. 
Persona C10/M10 ID Card Printer Service Manual (Rev. 4.0) 
94
Aligning the Headlift Sensor 
Step Procedure 
1
Close the Upper Imaging Assembly; leave the Top Cover open. 
2
Apply power to the printer; press both the on-line and on/cancel buttons at the 
same time. You will hear the Headlift motor energize for a moment and then 
stop — it sounds like a low-pitched winding noise.  
Positioning the Headlift Cam 
Step Procedure 
1
Examine the eccentric cam in the middle of the Headlift Shaft Assembly. The 
cam is a black, semi-round cylinder ¾-inch wide positioned midway across the 
width of the Upper Imaging Assembly, riding against the Cam Lift Plate and a 
thin metal plate called a Cam Follower Spring. 
2
Run the Headlift Alignment procedure above. 
3
Watch the rotation of the eccentric cam. 
The eccentric cam will make one complete rotation (360°) 
counterclockwise; it should come to rest with the fattest portion of the cam 
face down, pushing the Cam Lift Plate to its lowest position. 
The lifter arm of the Headlift Switch should be depressed, opening the 
contacts of the Headlift Switch. (It should be an open contact when 
depressed; with the arm released the contacts will close.) The Headlift 
Switch could be malfunctioning if the fat portion of the cam stops at the 
highest point. Adjust the mounting screw of the Headlift Switch; it may be 
too tight.  
Ensure that the switch is positioned correctly on the Print Assembly 
Sideplate. Make sure the switch activates when the lifter arm is depressed. 
This can be measured with an ohmmeter for continuity. 
Check the rotation of the cam during the Headlift Alignment procedure if 
difficulty persists. Normally, the cam should rotate counterclockwise (from 
the front of the printer). 
If the camis rotating clockwise, the HeadliftMotor cable connection (J15 on 
the Print Circuit Board) is reversed.