Star Micronics SP2000 Benutzerhandbuch

Seite von 81
36
1-2-8. Other Commands
FUNCTION
Cancels printer buffer & Initialize printer
CODE
<CAN>
(18)H
OUTLINE
Clears the data buffer and line buffer and initializes all commands
that have already been set.  <CAN> is executed not when taking
data from the reception buffer, but when it is received from the
host.  The select/deselect states in the DC1 and DC3 modes, and
external device drive conditions set by <ESC> <BEL>
 n1
 and
 n2
do not affect the automatic status valid/invalid conditions.
Print Sample
Deselects printer
CODE
<DC3>
(13)H
OUTLINE
Data following this code is ignored when the printer receives a
<DC3> code.
The deselect mode is canceled by <DC1> code.
FUNCTION
Set select mode (Default)
CODE
<DC1>
(11)H
OUTLINE
When the printer receives a <DC1> code, the deselect mode is
canceled and data following this code is input to the buffer.
FUNCTION
Beeps the buzzer
CODE
<RS>
(1E)H
OUTLINE
A short alarm is generated by the printer.