Siemens S7-400 Benutzerhandbuch

Seite von 638
Analog Modules
5-49
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
Connecting Four-Wire Transmitters 
M+
M–
M+
M–
M
ANA
Sensor, 
for example,
pressure gauge
+
Four-wire 
transmitter
+
U
 H
* Connection required in the case of modules with M
ANA
P
P
*
*
Figure 5-12
Connecting Four-Wire Transmitters to an AI
SM 431; 8 x 13 Bit: Connecting Four-Wire Transmitters
To ensure that the permissible value for U
CM
 is not exceeded, you must connect
the M– cables to M
ANA
.
M
Sensor, for example,
pressure gauge
+
Four-wire 
transmitter
+
U
 H
M
I
+
MI
+
M–
M
V+
M
V+
M
I
+
M
I
+
M–
P
P
Figure 5-13