Vanguard Managed Solutions 7300 Series Benutzerhandbuch

Seite von 227
 
B-5
T1/E1/PRI Cables
T1/E1/PRI Cables
Introduction
This section describes the cable requirements for the T1/E1/PRI Card.
Cable 
Requirements
The T1/E1/PRI card requires one of the following cables to connect to the
T1/E1 network:
• RJ48-to-RJ48 twisted-pair cable to connect to a T1 network (minimum 26 
AWG wire).
• RJ48-to-RJ48 twisted-pair cable to connect to a E1 network having 120-Ohm 
line impedance. (ETSI-TBR-013 requires that this cable be constructed of 
solid conductors of 0.4mm to 0.6mm.)
• 2 BNC-to-BNC 75-Ohm coaxial cables to connect to an E1 network that has 
75-Ohm line impedance.
RJ48C Connector
This table describes the RJ48C connector pinout:
BNC Adapter Cable A BNC adapter cable provides two BNC connectors to connect to an E1 network
with 75-Ohm
 
line impedance. Use these adapter cables:
• BNC connector marked XMIT for transmit (TX). 
• BNC connector marked REC for receive (RX).
Pin
Function
1
Receive Ring
2
Receive Tip
3
(no connection)
4
Transmit Ring
5
Transmit Tip
6
(no connection)
7
(no connection)
8(no connection)