RAD Data comm Modular Access Device with Integrated Router Benutzerhandbuch

Seite von 224
Chapter 5  Setup Menu 
FCD-IPM Installation and Operation Manual 
5-28 
Interface Parameters Menu
 
 
Table 5-14.  Link Settings 
Parameters Possible 
Values Description 
Status 
Enabled 
Disabled 
 
 
Backup 
Transmits frames. Normally you want all links in enabled status 
Does not transmit frames. The link may be permanently 
disabled, for example, when testing. A disabled line freezes all 
link operation, including connection attempts and forwarding. 
If a link is defined as backup to another, then whenever the 
main link operates normally, the backup link is disabled. If the 
main link fails, the backup link begins to operate and become 
enabled. You must that the routing settings are correct so that 
traffic will be forwarded to the desired destination via the 
backup link. When you restore the main link connection, the 
backup link becomes disabled again. 
Type 
Synchronous 
 
Asynchronous 
 
 
Frame Relay 
Data bits are transmitted at a fixed rate, because the sender and 
the receiver are synchronized 
Units of data are sent one character at a time. Characters are 
preceded by start bits and followed by stop bits, which provide 
synchronization at the receive terminal. 
A packet-switching protocol for connecting devices on a WAN 
Connection Type  Originate only 
Answer only  
Answer & Originate  
If the link is to be used to connect to the Internet or Intranet 
If the link is to be used for receiving remote access connection 
If the link is to be used for both incoming and out going 
connections (not simultaneously) 
 
Note: This parameter only affects dial-up link types 
(asynchronous with modem or ISDN). For leased-line links,select 
Answer-only
. 
Connection 
Timeout (sec) 
 
 
Specifies the connection timeout. The remote side has to answer 
within the time allotted with the Connection Timeout. If within 
this time there is no response, you are informed that the remote 
side is no longer active. 
This is meaningful only if the link is configured for PPP protocol. 
Note: Connection timeout is only configured when the PPP 
protcol is used.  
Control Signals 
Mode 
ON, Ignore
  
Determines whether the control signals are ignored or 
acknowledged by link hardware 
Baud Rate 
 
 
Specifies the rate at which data is sent across the link 
Note: For Synchronous and Asynchronous DCE links only.