Huawei MC509 Benutzerhandbuch

Seite von 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Serial Port Control Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
55 
 
3: Eight data bits and one stop bit (default value after startup) 
<parity>: 
0: odd parity (reserved and not supported at present) 
1: even parity (reserved and not supported at present) 
2: MARK (reserved and not supported at present) 
3: SPACE (default value after startup) 
 
 
 
AT+ICF is equivalent to AT+IFC=3,3
 
When the check bit of the physical serial port on the TE is set to None or Space, the TE 
can properly communicate with the MT. 
 
5.5 +IPRCommand for Setting the Fixed Baud Rate 
5.5.1 Syntax 
Command 
Possible Response(s) 
+IPR[=<rate>] 
<CR><LF>OK<CR><LF> 
In case of an MT-related error: 
<CR><LF>ERROR<CR><LF> 
+IPR? 
<CR><LF>+IPR:<rate><CR><LF> 
<CR><LF>OK<CR><LF> 
+IPR=? 
<CR><LF>+IPR:(supported automatic detection 
baud rate list),(supported <rate> list) 
<CR><LF> 
<CR><LF>OK<CR><LF> 
 
5.5.2 Interface Description 
This command sets the baud rate of the current physical serial port on the MT. The 
default value upon startup is 115200