Huawei MC509 Benutzerhandbuch

Seite von 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Call Control Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
80 
 
<state>: Specifies the call state. The values are as follows: 
0: active 
1: held (not supported at present) 
2: dialing 
3: alerting (not supported at present) 
4: incoming 
5: waiting (not supported at present) 
<mode>: Specifies the call type. The values are as follows: 
0: voice 
1: data 
<mpty>: Specifies the multiparty call
The values are as follows: 
0: non-multiparty call 
1: multiparty call (not supported at present) 
<number>: Specifies a call number. It is a string with double quotation marks. Allowed 
characters include only 0
–9, *, #, and +. In addition, the + symbol can only be at the 
start of the number. 
<type>: Specifies the type of a call number. "145" indicates an international number, 
and "129" indicates a national number. For details, see section 15.5 "Phone Number 
Type."
 
7.12.4 Example 
AT+CLCC 
+CLCC:1,0,0,0,0,
”13801000841”,129 
 
OK 
7.13 ^DTMFTwo-Stage Dialing Command 
7.13.1 Syntax 
Command 
Possible Response(s) 
^DTMF=<call_x>,<dtmf_digit> 
<CR><LF>OK<CR><LF> 
In case of an MT-related error: 
<CR><LF>+CME ERROR:<err><CR><LF>