Alloy Computer Products BWS-136 Benutzerhandbuch

Seite von 18
 
BWS-136 User Manual_amend.doc 
- 31 - 
e.g. $SOS0D0A (CR/LF)   
G S 
OT
: Timeout 
0~65535 
(unit: ms) 
e.g.$SOT500 
 
G S 
OL
: Data Length 
0~1024 
e.g.$SOL20 
G S 
OF
:IP Filtering 
0
: Disable 
1
:Enable 
Access 
Control 
G S 
OI
: Authorized IP 
e.g.$SOI192.168.16.1:192.1
68.16.9
(Starting IP:Ended 
IP) 
TCP Server 
G S 
VP
: Listen Port 
1~65535 
e.g. $SVP4000 
G S 
CI
: Destination IP 
e.g.$SCI192.168.16.200 
G S 
CP
: Destination Port 
e.g.$SCP4001 
TCP Client 
G S 
CC
: Connection   
Logic 
0
: Reserved for PPPoE 
1
:Establish connection when 
Serial Data in 
 S 
YC
: System mode 
R
: Reboot system 
F
: Reset to default setting 
and reboot 
D
: Set current setting as 
Default setting 
System 
 S 
EI
: Exit console   
 
DIO 
 S 
DM: 
Set Digital I/O   
mode 
I
 Input    Output 
H
 pull high, L pull low 
 
BWS-136 User Manual_amend.doc 
- 32 - 
e.g. $SDMI:0,4,5 
set DIO0, DIO4, DIO5 as 
input       
       
$SDMO:1,H,2,L,4,H,7,L 
set DIO1 high ,DIO2 low, 
DIO4 high, DIO7 low as 
Output 
G  
DM: 
Get Digital 
 
I/O mode 
e.g. $GDM 
the response is 
%GDM I,O,O,O,I,I,O,O 
G  
DI: 
Get DI channel 
status 
e.g. $GDI 
the response is 
%GDI 0=1,4=0,5=1 
It stands for 
DIO0=1,DIO4=0,DIO5=1 
Remark: Italic font stands for Command String 
 
CR/LF (two bytes)
Both command from host and echo from 
BWS-136 are terminated with a Carriage Return (ACSII code Hex 
0d) and Line Feed (ASCII code Hex 0a). Therefore please 
remember to add CR/LF
 
at the end of command line in the terminal 
emulation program. 
 
All command strings are in Upper Case