METRObility Optical Systems R111-16 Benutzerhandbuch

Seite von 16
12
  User Guide
Technical Specifications
Data Rate
Data Rate ______________________ 10Mbps half duplex; 20Mbps full duplex
Bit Delay __________________________________________________ < 5 bits
Environmental
Power ___________________________________ 5V @ 1.0 Amp, 5W average
Operating Temperature ____________________________________ 0
°
 to 50
°
 C
Storage Temperature ____________________________________ -30
°
 to 70
°
 C
Operating Humidity _________________________ 5% to 95% non-condensing
Weight _______________________________________________ 5 oz (0.14 kg)
Network Connections
Twisted-Pair Interface
Connector __________________________________ Shielded RJ-45, 8-pin jack
Impedance ________________________________________ 100 Ohms nominal
Signal Level Output ______________________________________ 2.0 to 2.8V
Signal Level Input __________________________________ 350mV minimum
Supported Link Length _________________________________________ 100m
Cable Type ___________________________________ Category 3, 4 or 5 UTP
(For NEBS Level III and EN55024:1998 compliance, use only
Category 5 STP cables.)
Singlemode F/O Interface
(R111-16)
Connector _____________________________________________________ ST
Wavelength ________________________________________________ 1310nm
RX Input Sensitivity ______________________________ -32.5 dBm minimum
Output Power ___________________________________ -27 dBm to -17 dBm
Supported Link Length ___________________________ up to 14km full duplex
Cable Type ___________________________________________ 9/125 
µ
m F/O
Thinnet Coax Interface
(R111-12)
Connector __________________________________________ BNC receptacle
Termination ___________________________________ User Selectable Jumper
Supported Link Length ____________________________________ up to 185m
Cable Type ______________________________________ RG-58 coaxial cable