User and Privilege Settings
Purpose:
Defines users to the system.
Command: [SECURE privilege]
SET USER <name> RO|RW|SECURE <password>
CLEAR USER <name>
User name and passwords are specified as 1 to 15 alphanumeric characters.
Status Command: [SECURE privileges]
GET USERS
Performance and Alarms
Configure Alarm Thresholds
Purpose:
Configures the OAM alarm threshold and windows for CRC, Errored Symbol Period, Errored Frame Event, Errored
Frame Period, and Errored Frame Seconds Summary events.
Frame Period, and Errored Frame Seconds Summary events.
Command: [RW,SECURE privilege]
SET [<interface>] <type> EVENT THRESHOLD <number> [WINDOW <number>]
• <interface> can optionally be specified to target a specific interface; when not specified, both interfaces are tar-
geted. <interface> must be either NETWORK or SUBSCRIBER.
• <type> is one of CRC|FRAME|FRAME PERIOD|FRAME SECONDS|SYMBOL PERIOD.
• <number> is an integer value whose range is dependent on the <type> and interface speed as specified by
IEEE 802.3ah. For convenience, MINIMUM and MAXIMUM are keywords that can be substituted for <number>
to set the values to the minimum and maximum values specified in IEEE 802.3ah.
to set the values to the minimum and maximum values specified in IEEE 802.3ah.
• [WINDOW <number>] can be optionally specified; if not specified, the pervious value is retained.
Example: SET FRAME PERIOD EVENT THRESHOLD 1
Example: SET SUBSCRIBER CRC EVENT THRESHOLD MINIMUM WINDOW MAXIMUM
Status Command: [all privileges]
GET [NETWORK|SUBSCRIBER] EVENT THRESHOLD