2.9.3 Connecting to a 100-pin 0.65mm Pitch Foot Pattern (Part 2) 
Here following is a procedure of connecting to a 100-pin 0.65mm pitch foot pattern on the user system using the M3T-
DIRECT100S (not included). For details on the M3T-100LCC-DMS (not included) and M3T-DIRECT100S (not included), 
refer to each user's manual. 
 
(1)  Attach the M3T-DIRECT100S to the user system. 
(2)  Attach the M3T-100LCC-DMS to the M3T-DIRECT100S. 
(3)  Attach the CN2 side of the M30800T-PTC to the J4 side of the M306NKT-EPB. 
(4)  Attach the M30800T-PTC to the M3T-100LCC-DMS. 
 
 
M3T-100LCC-DMS
(not included)
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65mm pitch
No. 1 pin
User system
M3T-DIRECT100S
(not included)
M3T-FLX160-EPB
M306NKT-EPB
(PRQP0100JB-A) foot pattern
   
 
Figure 2.11 Connecting to a 100-pin 0.65mm pitch foot pattern (Part 2) 
 
  CAUTION 
Note on Connecting the User System: 
 
z
 Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and 
user system. 
 
IMPORTANT 
Notes on Connectors of the Converter board: 
 
z
 The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations. 
z
 The connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20 
insertion/removal iterations.