UIDE
 
 
Note: Since the defective pixel requires placement of reference sources it is necessary to implement 
this command in ‘sub-protocol’ form.  See paragraph 
X
7.7
X
 for details. 
5.3.38 CMD_IRCON_LOAD_LUT  
Description:  Custom LUT table creation for radiometry.  Contact Lumitron for specifics. 
5.3.39 CMD_LOAD_RAD_PARAMS  
Description:  Custom load radiometric parameters for compile time software.  Contact Lumitron for 
specifics. 
5.3.40 CMD_RESET_PFV_COUNT  
Description:  Resets the processed FPA video frame count.  
Command Code: Enumeration for CMD_RESET_PFV_COUNT 
Argument Size: 0 
Argument: Null 
Note: none. 
5.3.41 CMD_CLEAR_CONTINUE_FLAG  
Description:  Clears (resets) the idle while fault continue flag.  
Command Code: Enumeration for CMD_CLEAR_CONTINUE_FLAG 
Argument Size: 0 
Argument: Null 
Note: Errors that are trapped during the boot process or while operating under normal conditions 
cause the embedded software to enter an idle routine.  While in this routine the host can check the 
error code and associated information.  Once the fault has been acknowledged the continue flag can 
be cleared and the software will resume where it left off. 
5.3.42 CMD_UNIFORMITY_TEST  
Description:  Command to initiate a uniformity test. 
Command Code: Enumeration for CMD_UNIFORMITY_TEST 
Argument Size: 0 
Argument: Null 
Note: This test is still under development. 
5.3.43 CMD_WRITE_UTILITY_MEMORY 
Description:  Write data to the utility memory.  The utility memory is external RAM that is interfaced 
through the Xilinx FPGA.  The data to be programmed will need to be written to the scratch pad (DSP 
memory location 0x00C0) before initiating this command.  
Command Code: Enumeration for CMD_WRITE_UTILITY_MEMORY 
Argument Size: size of UTIL_MEM_XFER 
Argument: See below. 
struct _UTIL_MEM_XFER{ 
 
UWord32 
addr;  
// Address in utility memory to read/write 
 
UWord16 
size;  
// Size in WORDS (Limit to 160) 
17