IBM ECS-320A Benutzerhandbuch

Seite von 63
S
ERIAL 
I
NTERFACE 
D
EVELOPERS 
G
UIDE
 
 
Size: 1 Word  
Description:  The member is divided into the following bit fields.  
Fan Speed Index: (Bits 0 - 2) Current internal fan speed index.  Read only data member. 
Base NUC table: (Bits 3 - 8) Current base NUC index.  Read only data member. 
Limit NUC table: (Bits 9 - 14) Current limit NUC index.  Read only data member. 
No Refresh: (Bit 15) Set to disable automatic NUC refreshes.  Only use this bit during specific 
operations (defective pixel detection).  Then clear when done. 
6.2.18 CameraConfig.radSWInfo  
Type: UWord16 
Size: 1 Word  
Description:  OEM radiometric software version ID of the loaded embedded application.  Read only 
data member. 
6.2.19 CameraConfig.alarm  
Type: UWord16 
Size: 1 Word  
Description:  This member is divided into the following bit fields for alarm state monitoring and other 
miscellaneous settings.  Read only data member(s). 
Overtemp Alarm State: (Bit 0) Current overtemp alarm state. 
Overtemp Acknowledge Alarm State: (Bit 1) Camera software acknowledge. 
Battery Level State: (Bit 2) Low battery state value. 
Battery Level Acknowledge State: (Bit 3) Camera software acknowledge. 
FPA TEC Disable State: (Bit 4) TEC disable state (due to over temp condition). 
Reserved Bits: (Bits 5 – 15). 
6.2.20 CameraConfig.calFlagRefs  
Type: UWord16 
Size: 1 Word  
Description:  Calibration flag ADC reference settings as copied from the active NUC mode.  These 
settings are used in subsequent calibrations that incorporate the internal calibration flag.  The variable 
is divided as follows.  Read only data member. 
Cold Reference Setting: (Bits 0 – 7) 
 
Hot Reference Setting: (Bits 8 – 15) 
 
6.2.21 CameraConfig.fpaInfo  
Type: UWord16 
Size: 1 Word  
Description:  This value is broken into FPA type and sub-type as configured by the manufacturer/OEM.    
The value is read on boot from the DSP data flash and can be used by the host to configure host 
application settings.  The variable is divided as follows.  Read only data member. 
FPA Type Identifier: (Bits 0 – 3) 
24