The following points should also be observed: 
 
•  Close the parasitic circuit  
•  Connect all devices to the potential equalizing cable as often as possible. Electrical 
conductors such as machine elements, metal tubes or supporting constructions should 
be integrated into the system. 
•  Protect the potential-equalization cable and connections against corrosion.  
•  Select the cross-section of the potential equalization cable according to the maximum 
equalization current.  
 
If these different measures do not correct the problem, a galvanic separation according to 
ISO 9549 may have to be installed. You may also want to consider the use of fiber-optic cables. 
15. Document 
releases 
 
Doc. Release 
Date 
Notes 
-10 
Jan. 16, 2007 
Original release 
 
Hardware and firmware: 
 
Firmware Version 
Date 
PCB Number 
1.0a 
Apr. 26, 2006 
Model DI-3: 66.0860.0015 
Model DI-4: 66.0862.0015