Problems and Error Messages
Troubleshooting
B - 2
The MSS completes its 
power-up and boot 
procedures, but 
thereÕs no noticeable 
serial activity.
There is a problem with the 
serial connection or the set-
up of the serial device.
Check the terminal setup and the 
physical connections, including 
the cable pinouts (see Appendix 
C). T
ry another serial device or 
cable, or cycle power on the MSS.
A rapidly-blinking OK LED 
may signal boot failure. 
Reboot the unit. When the MSS is 
running normally, the OK LED 
blinks every two seconds.
The terminal shows a 
Boot> prompt rather 
than a Local> prompt.
The MSS is not connected 
properly to the Ethernet.
Ensure that the MSS is Þrmly 
connected to a functional and 
properly-terminated network 
node. 
The MSS Ethernet address is 
invalid.
The MSS Ethernet address is 
located on the bottom of the unit. 
Use the Change Hardware 
command to set the correct 
address (see page B-5), then 
reboot. 
Init Noboot
 command was 
entered.
The MSS passes 
power-up diagnos-
tics, but attempts to 
download new Flash 
ROM code from a 
network host.
 If the OK LED blinks 
rapidly, the Flash ROM code 
may be corrupt.
Reboot the unit. If you get the 
same message, you will need to 
reload Flash ROM. See Reloading 
MSS Software
 on page D-3.
If you did not request a 
NetWare or TFTP boot, the 
ßash ROM code is corrupt. 
The unit will remain in boot 
mode.
Table B-1:  
Problems and Error Messages, cont.
Problem/Message
Error
Remedy