Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
 
1-40  
Revision January, 2008, Doc. Name: 2007PDD23000007 
Jetter Nano Series PLC 
A. HMI factory settings 
Baud rate: 9600, 8, EVEN, 1 (RS-232). 
Controller station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) 
communication is allowed.) 
Control area/status area: WR0 / WR10. 
NOTE
 
1)  Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication 
is allowed. 
2)  Only 1 Bit or 1 Word can be transferred for each communication. 
3)  In general, each register occupies max. 24 Bits. However, some registers occupies 8 Bits only. 
4)  Because the initial time of this controller is longer, it is recommended to set HMI startup delay time 
(Recommended time is 10 seconds). 
5)  When the register R is used for Double Word device, please set its format as signed format. (The default 
format in Screen Editor is signed format) 
B. Definition of controller Read/Write address 
Registers 
Read/Write Range 
Register Type 
Format 
Word No. 
Bit No. 
Data 
Length 
16 Bits Register 
WRn 
n:
0 ~ 32767 
N/A 
16 Bits 
32 Bits Register 
Rn 
n:
0 ~ 32767 
N/A 
24 Bits 
Only the first 16 bits are used for WRn registers. 
Only the first 24 bits are used for Rn registers, the highest 8 bits (Bit 24 ~ 31) are set to 0 by default setting. 
(24-bit Integer :  If in decimal format, the range is -8388608 ~ +8388607. If in hexadecimal format, the range 
is 0x000000 ~ 0xFFFFFF.) 
NOTE
  
1)  The difference between WRn and Rn: 
y
 
When using devices that the data length is in Word, only Bit 0 ~ 15 are valid for both of WRn and 
Rn registers. 
y
 
When using devices that the data length is in Double Word,  
if the read/write address format is set to WRn, the Bit 0 ~ 15 of WRn register is the low word of a 
read/write value, the Bit 0 ~ 15 of WRn+1 register is the high word of a read/write value.