Delta Electronics DOP-A/AE/AS Verbindungsanleitung

Seite von 137
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series 
Revision January, 2008, Doc. Name: 2007PDD23000007 
 
 
1-93 
MKS CT150 
A. HMI factory settings 
Baud rate: 9600, 7, E, 1. (RS-232) 
Controller Station number: 11. 
Control area/status area: None / None. 
B. Definition of controller Read/Write address 
Registers 
Read/Write Range 
Register Type 
Format 
Word No. 
Bit No. 
Data In Register 
Cn 
n: 0 ~ 25 
N/A 
Setup Register 
Cn 
n: 40 ~ 43 
N/A 
 
 
45 ~ 50 
 
 
 
90 ~ 97 
 
Error Count 
Err_CNT 
N/A 
LV Value 
LV_VAL 
N/A 
Printmark Error 
PRTMARK_ERR 
N/A 
Batch Counter 
BAT_CNT 
N/A 
Waste Counter 
WASTE_CNT 
N/A 
Line Speed 
LINE_SPD 
N/A 
Actual Cutting Length 
ACT_CUT_LEN 
N/A 
Contacts 
Read/Write Range 
Contact type 
Format 
Word No. 
Bit No. 
Reset RST 
N/A 
Jog Trim+ 
JOGTRIM_INC 
N/A 
Jog Trim- 
JOGTRIM_DEC 
N/A 
Read PI 
READ_PI 
N/A 
Activate Data 
ACT_DATA 
N/A 
Store Eeprom 
STR_EEPROM 
N/A 
Start/Stop START_STOP 
N/A 
Reset Mark Counter 
RSTMARK_CNT 
N/A