IFBD-HW03/04 Product Specifications Rev. 0.00 
 
3.6.6. SNMP 
Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default Settings)
Authentic Community 
Max. 15 char. of ASCII
 
“public” 
Trap Community 
Max. 15 char. of ASCII (Japanese lang. OK) 
 
“public” 
Trap Address (IP) 
0.0.0.0 to 255.255.255.255 
0.0.0.0   
SysContact 
Max. 78 char. of ASCII (Japanese lang. OK) 
 
None
 
SysName 
Max. 78 char. of ASCII (Japanese lang. OK) 
 
None
 
SysLocation 
Max. 78 char. of ASCII (Japanese lang. OK) 
 
None
 
EbableAuthenTrap 1/2 
3.6.7.  Secure Print Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default Settings)
Secure Print 
ENABLE/DISABLE 
ENABLE 
SSL Mode 
ALL 
RC4-40 
RC4-128 
DES-40 
DES-64 
3DES-192 
ALL 
3.6.8.  RAS Counter Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default Settings)
Compare Value 
0-99,999,999 = 
0x00000000-0x05F5E0FF 
 
99,999,999 
Send Mail 
ENABLE/DISABLE 
DISABLE 
To Address 
Max. 78 char. of ASCII
 
None
 
Check Interval(min.) 
1-10000 
10 
Offline ON/OFF 
OFF 
Paper Empty 
ON/OFF 
OFF 
Fault ON/OFF 
OFF 
3.6.9.  Memory Switch Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default Settings)
Code Page Setting 
Select from list
 
Normal 
Black Mark Sensor 
ENABLE/DISABLE 
DISABLE 
3.6.10.  SSL Identification Creation Settings (Web Only) 
3.6.10.1. 
Identification Information Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default 
Settings)
 
Country/Region Code
 
2-character character string
 
Blank
 
Prefecture Name
 
128-character character string
 
Blank
 
City or Town Name
 
128-character character string
 
Blank
 
Organization Name
 
64-character character string
 
Blank
 
Section Name
 
64-character character string
 
Blank
 
General Name
 
64-character character string
 
Blank
 
Mail Address
 
128-character character string
 
Blank
 
3.6.10.2. 
Time Limit Settings 
Variable Name
 
Setting Range 
 
Initial Value (Default Settings)
 
Date of Issue
 
Display Only 
 
Cannot be set because automatically generated 
 
Time Limit Date
 
to 2049/12/31
 
2049/12/31 
 
 
3-37