Nortel Networks AN/DC Benutzerhandbuch
Installing and Operating AN/DC and ANH-8/DC Systems
1-4
312410-A Rev 00
Service Console
You can attach an optional VT-100 console or equivalent to the AN/DC to monitor
the results of startup diagnostics and perform manual boot configurations; or you
can attach any AT-compatible modem to allow remote dial-in access to diagnostics
and configuration.
the results of startup diagnostics and perform manual boot configurations; or you
can attach any AT-compatible modem to allow remote dial-in access to diagnostics
and configuration.
Mounting Hardware
To rack-mount the AN/DC, you need an electronic enclosure rack that meets the
following specifications:
following specifications:
•
Heavy-duty steel construction
•
Electronic Industries Association (EIA) standard hole-spacing
•
Width of 19 in. (48.26 cm) and depth of 24 in. (60.96 cm)
If the rack’s rails do not have threaded holes, you must supply cagenuts to use
with the cagenut screws (see
with the cagenut screws (see
).
Verifying Site Requirements
Verify that your installation meet the requirements listed in this section.
•
•
•
Note:
To use the Netboot, Directed Netboot, or Local Boot configuration
options (see Chapter 3), there must be a local terminal connected the first time
that the ANH-8/DC powers up.
that the ANH-8/DC powers up.
Note:
The AN/DC should be installed only in dedicated equipment rooms
where access is limited to qualified service personnel.