Power Up/Down Test Procedures
Power Up/Down Test Procedures
The following test procedure is recommended primarily for power up and shutting down the EVM.
Whenever the EVM is running above an output load of 15 A
DC
, the fan should be turned on. Also, never
walk away from a powered EVM for extended periods of time.
1. Working at an ESD workstation, make sure that any wrist straps, bootstraps or mats are connected
referencing the user to earth ground before power is applied to the EVM. Electrostatic smock and
safety glasses should also be worn.
2. Prior to connecting the DC input source, VIN, it is advisable to limit the source current from VIN to
3.5-A maximum. Make sure VIN is initially set to 0 V and connected to J1 as shown in
3. Connect the ammeter A1 (0A to10A range) between VIN and J1 as shown in
4. Connect voltmeter (can optionally use voltmeter from VIN source if available), V1 across VIN as shown
in
5. Connect LOAD1 to J8 as shown in
Set LOAD1 to constant current mode to sink 0 A
DC
before
VIN is applied.
6. Connect voltmeter, V2 across J9 and J10 as shown in
.
7. Increase VIN from 0 V to 36 V
DC
.
8. Observe that VOUT is regulating when VIN is at 36 V.
9. Increase VIN to 48 V.
10. Increase LOAD1 from 0 A to 15 A
DC
.
11. Turn on fan making sure to blow air directly on the EVM.
12. Increase LOAD1 from 15 A
DC
to 30 A
DC
.
13. Decrease LOAD1 to 0 A.
14. Decrease VIN from 48 V
DC
to 0 V.
15. Shut down VIN.