                                                                                           Troubleshooting Procedures
    
5-3  
 
5.3 Troubleshooting Procedures
The built-in self test program and the disk resident diagnostics program (PC-Doctor) 
are useful tools in computer troubleshooting. However, if the computer has a power, 
keyboard or display problem, you must first solve this problem before running 
diagnostics. If the computer powers up and displays messages on the LCD or emits a 
series of beeps, skip to Paragraph 5.3.3 for further instructions.
5.3.1 Troubleshooting a Power Supply Problem
If the computer does not power up when the Power Switch is set to the ON position, 
you most likely have a malfunction in the power subsystem (loss of power at the AC 
outlet, faulty AC adapter, discharged Battery Packs, or faulty Power Supply on the Main 
Board). With a power problem, all LEDs are extinguished, the LCD screen is blank, the 
system does not respond when the suspend switch is pressed several times 
consecutively and no drive activity can be heard. The computer is unable to load 
software and displays no visible signs of activity.  To fault isolate a power problem, 
check the following:
AC adapter and Battery - Plug in the AC adapter and double-check all 
connections on the adapter and computer. Ensure that the Notebook Power 
switch is set to the On position and that the system is not in Suspend or 
sleep mode.
Measure the voltage at the AC outlet or plug in a known good appliance (e.g. 
a lamp) to verify that voltage is present. If the voltage is ok, try replacing the 
AC adapter.
Check to see that the battery packs are installed correctly and that the 
battery charge indicators on the front of the battery packs indicate the 
batteries are charged (try using a new battery pack if batteries are 
discharged).
If the AC outlet voltage, AC adapter, and battery packs test normal but the 
computer will not power up, try disconnecting the display cable from the 
base (refer to Section 6 for disassembly instructions) to see if a short in the 
display assembly has occurred.
If the display assembly appears to be normal, replace the Bottom Board as 
described in Section 6 and retest system.
5.3.2 Troubleshooting a Display Problem
If the LCD remains blank when you turn on the computer, and the status indicators