manifold Gas Supply pressure
(all models)
Fuel #
Low 
(millivolt only)
High
Natural 
Gas
(Lo) 2.2" WC
(0.55 kpa)
(Hi) 3.5" WC
(0.87 kpa)
propane (Lo) 6.3" WC
(1.57 kpa)
(Hi) 10.0" WC
(2.49 kpa)
Table 4
Inlet Gas Supply pressure 
(all models)
Fuel #
minimum
maximum
Natural Gas
5.0" WC
(1.24 kpa)
10.5" WC
(2.61 kpa)
propane
11.0" WC
(2.74 kpa)
13.0" WC
(3.23 kpa)
Table 3
Gas pressure - All models
Tables 3 and 4
 show the appliances' inlet and 
manifold gas pressure requirements:
REQUIREmENTS  FOR  THE  COmmON-
WEALTH OF mASSACHUSETTS
Installation of these fireplaces are  approved  
for installation in the US state of Massachu-
setts if the following additional requirements 
are met:
•  Install  this  appliance  in  accordance  with
Massachusetts Rules and Regulations 248 
C.M.R. Sec. 5.08 2(a) through 2(e).
•  Installation and repair must be done by a
plumber or gas fitter licensed in the Com-
monwealth of Massachusetts.
•  The flexible gas line connector used shall
not  exceed  36  inches  (92  centimeters)  in 
length.
•  The individual manual shut-off must be a
T-handle type valve.
NEW YORK CITY, NEW YORK (mEA)
Installation of these fireplaces are approved for 
installation in New York City in the US state of 
New York (approval no. MEA 417-05-E), if the 
following additional requirements are met - 
•  An outside air kit (FOAK-4 or FOAK-4LD)
must be installed. See Figure 22 on Page 
16.
Orifice Sizes -  Sea Level to High Altitude
(All models)
These appliances are tested and approved for 
installation at elevations of 0-4500 feet (0-1372 
meters)  above  sea  level  using  the  standard 
burner orifice sizes (marked with an "*" in Table 
5).  For elevations above 4500 feet, contact your 
gas supplier or qualified service technician. 
deration  -  At  higher  elevations,  the  amount 
of BTU fuel value delivered must be reduced 
by either:
•  Using gas that has been derated by the gas
company. 
•  Changing the burner orifice to a smaller size
as regulated by the local authorities having 
jurisdiction and by the (USA) National Fuel 
Gas  Code  NFPA  54/ANSI  Z223.1  -  latest 
edition or, in Canada, the CAN/CSA-B149.1 
codes - latest edition.
Install the appliance according to the regulations 
of the local authorities having jurisdiction and, 
in the USA, the National Fuel Gas Code NFPA 
54 / ANSI Z223.1 - latest edition or, in Canada, 
the CAN/CSA-B149.1 - latest edition.
NOTE: Flame appearance will diminish 4% per 
thousand feet.
Gas Valve diagrams
See Figure 1 for Millivolt models and Figure 2 
For Electronic Models.
HI
LO W
HT
PT
HT
PT
PILO
T
PIL
OT
ON
it
OFF
IN
OUT
manifold pressure Tap
Inlet pressure Tap
pilot Adjustment
Screw
HI/LO Variable 
Flame Height 
Adjustment
main Gas 
Control Knob
OFF/pILOT/ON
Figure 1 - 
SIT Millivolt  Gas Valve
Figure 2
 - Honeywell Electronic  Gas Valve
FF
O
NI
P
S
I
N
O
L
O
RT
N
O
C
GI
N
TIER
manifold pressure 
port
ON / OFF Switch
Inlet 
pressure
port
Electronic Gas 
Control Valve
Test  gauge  connections  are  provided  on 
the  front  of  the  millivolt  gas  control  valve, 
identified  IN  for  the  inlet  and  OUT  for  the 
manifold side. A 1/8" NPT Test gauge connec-
tion is provided at the inlet and outlet side of   
the electronic gas control valve adjacent to the 
outlet to the main burner.
Propane tanks are at pressures that will cause 
damage to valve components.  Verify that the 
tanks have step down regulators to reduce the 
pressure to safe levels.
These appliances must be isolated from the 
gas supply piping system (by closing their 
individual manual shut-off valve) during any 
pressure  testing  of  the  gas  supply  piping 
system  at  test  pressures  equal  to  or  less 
than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off 
valves must be disconnected from the gas 
supply piping system during any pressure 
testing of that system at pressures greater 
than 1/2 psig (3.5 kPa).
These appliances must not be connected to a 
chimney or flue serving a separate solid fuel 
burning appliance.
Electronic models with
Fixed-Rate Gas Valve
Natural Gas
propane Gas
model
Input Rate
(bTU/HR)
Input Rate
(bTU/HR)
mpb3328
17,500
17,500
mpb3530
20,000
20,000
mpb4035
30,000
28,000
mpb4540
31,000
29,000
Table 2
Electronic models - These electronic appliances 
have a fixed rate gas valve and an electronic 
intermittent  pilot  ignition  system.    External 
electrical  power  is  required  to  operate  these 
units.  The  BTU  Input  for  these  appliances  is 
shown in Table 2.
burner Orifice Sizes 
Elevation 0-4500 feet ( 0-1372 meters)
model
Series
Nat.Gas
drill size (inches)
propane
drill size (inches)
MPB-3328
#47 (.0785") *
39L66 •
#1.2m (.048")*
99K78 •
MPB-3530
#44 (.086") *
60J80 •
#55 (.052") *
19L52 •
MPB-4035
#37 (.104") *
24m10 •
1/16" (.0625") *
21L01 •
MPB-4540
#36 (.1065") *
18L40 •
#52   (.0635") *
37G00 •
Table 5
* Standard size installed at factory
•  Part /Cat. Number