Honeywell DH150 Benutzerhandbuch

Seite von 60
TrueDRY DH150
 
 
69-2271EFS—01
Install TrueDRY DH150 according to National Electric Codes.
Dimensions:
Specifications
Product weight: 134 lbs
Shipping weight: 164 lbs
Shipping dimensions: 28 1/4 in. H x 42 in. W x 24 in. D
Media Filter: MERV 11, 16 in. H x 16 in. W x 2 in. D
Drain connection: 3/4-in. threaded female NPT
connection, with attached 3/4-in. male connection.
Duct connections: Round 10 in. and 6 in. inlets. Oval
10 in. x 4 in. outlet.
Cabinet: 20 gauge galvanized steel powder-coat
painted.
Input ratings
•  Electrical input voltage: 120VAC—1 Phase—60 Hz
nominal
•  Input current: 6.9 amps
Output ratings
•  Power transformer to R/C terminals: 24VAC,
0.85A
•  Energy Performance: 3.6 pints per kilowatt hour
(KWH).
Standards and approval body requirements
ETL tested per UL standard 474 (ducted dehumidifier.)
Dry-Bulb 
Temp
Wet-Bulb 
Temp
Intake 
Humidity
Capacity 
(Pints/Day)
80°F
70°F
60% RH
150
70°F
61°F
60% RH
116
60°F
52°F
60% RH
88
Home Size 
(square ft)
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor (pints/day) 50% RH Indoor (pints/day) 40% RH Indoor (pints/day)
2080
49–54
55–58
71–78
2600
61–68
65–72
90–97
3120
75–82
79–86
95–110
* Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger homes can be
adequately served with less capacity. Actual requirements may vary.
Airflow versus external static pressure 
(0–1 in. water pressure) with collars attached
0 in. WG
415 CFM
0.4 in WG.
365 CFM
FRONT VIEW
6 DIAMETER
REAR VIEW
SIDE VIEW
37-1/2 (953) WITHOUT COLLARS
39-1/2 (1003) WITH COLLARS
19-15/16
(506)
20-5/8 (524)
10 DIAMETER
M27792
Insulation: R value 1
Compressor: Rotary-style
Refrigerant: 2 lb., R-410.A
Operating Temp Range (outside cabinet): 
56ºF-95ºF (13ºC-35ºC)
Operating Humidity Range: 0-99% RH