Natural
Propane
Thermal
AFUE
Height
Depth
Width
TOP-VENT 
with Electrical Service Cord
3508332
3508331
35,000
28,000
80.0
75.0
72½"
10¼"
14
⅛"
One
240
0.8
Intermittent
95
3508732
3508731
35,000
28,000
80.0
75.0
72½"
10¼"
14
⅛"
One
240
0.8
Standing
90
5008732
5008731
50,000
40,000
80.0
74.3
81"
10¼"
14
⅛"
Two
350
2.2
Standing
99
5508332
5508331
55,000
44,000
80.0
76.0
87"
10¼"
14
⅛"
Two
440
3.0
Intermittent
113
6508732
6508731
65,000
48,000
74.0
74.0
87"
10¼"
14
⅛"
Two
440
3.0
Standing
107
DIRECT-VENT 
with Electrical Service Cord
4007332
4007331
40,000
32,000
80.0
75.0
77
⅜"
11¾"
14
⅛"
One
325
2.0
Intermittent
126
4007732
4007731
40,000
32,000
80.0
75.0
77
⅜"
11¾"
14
⅛"
One
325
2.0
Standing
126
5507332
5507331
55,000
44,000
80.0
76.0
87"
11¾"
14
⅛"
Two
440
3.0
Intermittent
140
6257732
6257731
62,500
50,000
80.0
76.0
87"
11¾"
14
⅛"
Two
440
3.0
Standing
140
TOP-VENT MAGNUM HIGH-EFFICIENCY 
with Electrical Service Cord
6008532
6008531
60,000
49,200
82.0
78.0
80¼"
10¼"
14
⅛"
Two
440
3.0
Standing
121
ELECTRIC COUNTERFLOW
Btu/hr at 
240V:  
31,400
Btu/hr at 
208V:  
23,600
Minimum 
Voltage:  
207V
Maximum 
Voltage:  
253V
72½"
7"
14
⅛"
One
375
40.0
N/A
60
Accessories
Rear and Side Outlet Accessories 
Allows heat to be ducted into a rear or side room.
6801
Rear-Outlet Register with 10" Boot and Damper for Top-Vent Models · 9 lbs.
6802
Rear-Outlet Register with 1" Boot and Damper for Top-Vent Models · 5 lbs.
6501
Rear-Outlet Register with 10" Boot and Damper for Electric Models · 7 lbs.
6701
Side-Outlet Register with 10" Boot and Damper for Top- and Direct-Vent Models  · 11 lbs.
6702
Side-Outlet Grille for Top- and Direct-Vent Models  · 2 lbs.
Front Diffusing Grilles 
-
 
A snap-on grille used to divert heat to the right, left or both directions.
6703
Two-Directional Diffuser Grille for All Models  · 3 lbs.
6704
One-Directional Diffuser Grille for All Models  · 3 lbs.
Venting Accessories
4318
Vent Shield Deflector · Insulated, galvanized metal sheet for Direct-Vent Models · 4 lbs.
9307
Thin Wall Collar · Wall thicknesses from 1" to 5".  Used with Direct-Vent Models  · 4 lbs.
9308
Vent Cap Guard · Protects pedestrian traffic from heat of the direct-vent cap  · 3 lbs.
9806
Direct-Vent Tube Extension - 12"  Length · 11 lbs.
9807
Direct-Vent Tube Extension - 15"  Length · 11 lbs.
9808
Direct-Vent Tube Extension - 24" Length · 11 lbs.
9901
Top-Vent Starter Kit · Contains starter hold down plate, oval-to-round adapter and two pieces of oval pipe.  · 9 lbs.
9902
Top-Vent Adapter for top-vent, freestanding (not recessed) installations  · 3 lbs.
Finish Items
4701
Trim Strip Accessory · Metal finishing moulding strips painted the same color as the furnace for all models  · 4 lbs.
9812
Top-Vent Enclosure - 12" · A metal enclosure, painted the same color as the furnace, to enclose the vent pipes  · 4 lbs.
9824
Top-Vent Enclosure - 24" · A metal enclosure, painted the same color as the furnace, to enclose the vent pipes.  · 8 lbs.
9836
Top-Vent Enclosure - 36" · A metal enclosure, painted the same color as the furnace, to enclose the vent pipes.  · 12 lbs.
Conversion Kits
 - Current models only · 1 lb.
Btu Size
Natural to 
Propane
Propane to 
Natural
35,000
7685
7692
40,000
7686
7693
50,000
7687
7694
55,000
7688
7695
60,000
7691
7698
65,000
7690
7697
62,500
7689
7696
High Altitude Models
Hard Wire Adapter 
Model 9940 - 1 lb.
Model Number
Btu/hr 
Input 
Rating
Btu/hr 
Output 
Rating
3144030 - 9.2 kW
Dimensions
Blower 
Speed
CFM 
115V
Gas connection:  ½"   ·   Equipped with a 24V control valve and wall thermostat   ·   All gas models are rated for 4,500' elevation 
© 2008 Williams Furnace Co.                         Printed in U.S.A.                 All Rights Reserved               Subject to Change without Notice                     L1158       5/08
Conversion Kit Available
Forsaire Counterflow Furnaces
Conversion Kit Available
Conversion Kit Available
Amps
Pilot Type
Shipping 
Weight 
(lbs.)
Efficiency %
                                              
  Important
·  
Read owner's manual before using/installing.
·  
Photographs are representative.
·  
Check local codes and ordinances for permitted uses.
· 
 Consult installation manual for clearances prior to installation.
·  
We reserve to right to amend product specifications without notice.
·  
Installation and servicing recommended by a qualified service person.
·  
Venting must comply with the installation manual.
· 
 New York approval MEA197-82E Vol 111 on direct-vent models only.
·  
Massachusetts approval G3-0305-171
·  
Please read the warranty for any limitations for disclaimers.
·  
Combustion chamber carries a ten-year limited warranty.  All other           
pi
parts carry a one-year limited warranty.
Dimensions and Clearances
Top-Vent
4" to Intersecting Wall
4" from Top of Furnace to Ceiling/Overhang
2" from Top of Furnace to Ceiling on 60085 Series
0" to Finished Floor
Direct-Vent
4" to Intersecting Wall
4" from Top of Furnace to Ceiling/Overhang
0" to Finished Floor
59" from Finished Floor to Centerline of Vent Cap for Model Series: 
40073 and 400773
68½" from Finished Floor to Centerline of Vent Cap for Model
250 West Laurel Street · Colton, California 92324 USA
(909) 825-0993 · Fax:  (909) 370-0581 or (909) 824-8009
Consumer Line:  (888) 256-6465
Homeowner Assistance:  (909) 426-0978
www.e-wfc.com