flue damper
10/27/03  djt
Flue Damper Closed for Unvented 
Operation and Maximum Heat 
Output
Flue Damper Locked Open 
to a Minimum Venting Area 
of 34 sq. in. (for areas where 
unvented products are not 
permitted)
NOTE: For round flue opening 
minimum flue diameter (D) - 7”. 
For square or rectangular flue 
opening, length x width (L x W) 
must equal 30 sq. in.
T104
Fig. 1  Minimum flue diameter and flue damper positions.
12”
vent370-2
Ventilation options 
3/26/99   djt
VO370-2
Fig. 2  Ventilation options for confined space.
Option 1 
- Vents to 
Adjoining 
Room
Option 2 - 
Remove Door 
to Adjoining 
Room
Option 3 - 
Vents to 
Adjoining 
Room
12”
WARNING:  Air openings that provide fresh air from an adjoining unconfined space shall not be blocked 
or obstructed in any way.  Installation of unit should allow a minimum of 2” clearance from any part of the 
heater to any of the ventilation openings.