Panasonic AG-3DP1G Benutzerhandbuch

Seite von 140
5
Chapter
4
Adjustments
and
Settings
for
Recording
Externally Locking the Time Code
The time code generator built into your camera may be 
locked to an external generator. It is also possible to lock 
an external time code generator to the internal generator.
Connections for externally locking the 
time code (examples)
As illustrated, both the reference video signals and the time 
code must be input.
Example 1 :  Locking the time code to 
external signals
Referencetime
code
Referencevideo
signal
TCIN
GENLOCKIN
 NOTE
•  Use an HD Y reference signal as reference video signal.
•  During HD-Y signal input in 720P system mode, GENLOCK 
input for the video signal is applied but the time code is 
delayed by 1 field.
•  If the reference GENLOCK input signal becomes irregular, 
recording cannot be performed normally and the continuity 
of the time code cannot be guaranteed. When the reference 
GENLOCK input signal becomes irregular, the unit resets the 
L/R section of the camera and is restarted. 
(During this process, the image is disturbed.)
•  The input signal of the RETURN IN connector can be locked 
externally if the menu option GENLOCK SEL in the OTHER 
FUNCTIONS screen is set to RETURN IN.
Example 2 :  Locking the time code of this 
unit and external equipment to 
the time code from an external 
time code generator
Referencevideo
signal
Externaltimecode
generator
TCIN
GENLOCKIN
 NOTE
When the system mode is 1080/23.98PsF, use the HD signal of 
23.98PsF as a reference signal and input a 24-frame time code 
to the TC IN connector.
To externally lock the time code
Follow the steps below.
1
TurnonthePOWERswitch.
2
PositiontheTCGswitchatF-RUN.
3
SettheCOUNTERbuttontoTC.
4
Supplyaphase-relationshipreference
timecode(thatconformstothetimecode
requirements)andreferencevideosignals
totheTCINandGENLOCKINconnectors,
respectively.
•  Now the built-in time code generator is locked to the 
reference time code.
•  When locked to an external time code generator, the 
time code is at all times locked to the external time code, 
which is displayed as a highlighted value on the counter 
indicator. Do not engage the recording mode during the 
few seconds it takes for the sync generator to stabilize.
•  Once a slave relationship is established, the TC IN and 
GENLOCK IN connectors stay in slave status.
*
1
  
Note that the following events release slave status.
• When TC PRESET is performed
• The power is turned off
• The time code mode is switched
• The TCG switch is set to R-RUN
•  When REC FORMAT has been switched
*
1
  The slave status locks the time code to the TC IN input 
and the device will use this time code even if time 
code input should subsequently cease.
Setting the user bits when the time code 
is externally locked
To externally lock user bits, set the setting menu UB MODE 
(RECORDING SETUP screen) to EXT.
Regardless of an F-RUN or R-RUN setting of the TCG 
switch, the time code is slaved to user bit values input to 
the TC IN connector. 
For details, refer to [Setting Time Data] (page 59) and 
[Setting User Bits] (page 61).
To unlock the externally locked time code
Discontinue external time code supply, then position the 
TCG switch at R-RUN.