Transition Networks SGETF1014-100 Benutzerhandbuch

Seite von 4
OPERATION 
Using Status LEDs
Use the status LEDs to monitor media converter operation in the network. 
P(o)W(e)R
Steady LED indicates connection to
external AC power.
RXF
(Fiber receive)  Flashing LED
indicates reception of data on fiber
link.
LKF
(Fiber link)  Steady LED indicates
fiber link connection.
RXC
(Copper receive)  Flashing LED indicates reception of data on
copper link.
LKC
(Copper link)  Steady LED indicates copper link connection.
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:
1.
Is the P(o)W(e)R LED on the media converter illuminated?
NO
Is the power cord properly installed in the media converter and at
the external power source?
Does the external power source provide power?
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 2.
2.
Is the LKC LED on the media converter illuminated?
NO
Check twisted-pair cables for proper connection.
Check twisted-pair cables for connection of all four pairs.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 3.
3.
Is the LKF LED on the media converter illuminated?
NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 4.
4.
Is the RXC LED on the media converter flashing?
NO
If there is NO ACTIVITY on the 1000BASE-TX port, proceed to step 5.
If there is ACTIVITY on the 1000BASE-TX port, disconnect and
reconnect the 1000BASE-TX cable to restart the initialization process.
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312.
YES
Proceed to step 5.
5.
Is the RXF LED on the media converter flashing?
NO
If there is NO ACTIVITY on the 1000BASE-SX/LX port, continue
below
If there is ACTIVITY on the 1000BASE-SX/LX port, disconnect and
reconnect the fiber cable to restart the initialization process.
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312.
YES
Contact Technical Support: (800) 260-1312.
PWR
RXF
RXC
LKF
LKC