Sterling 882.000254.00 Benutzerhandbuch

Seite von 91
7/50D Plus or 7/50D Controller 
Chapter 2:  Functional Description 
11 
2-3 Standard 
Features 
Mechanical Features 
Time-fill Capability.  The length of time allowed for material to drain from the station to its 
receiver.  During this time, the controller does not attempt to deliver any more material to the 
station. 
Volume-fill Capability.  The length of time a station’s vacuum valve remains open to allow 
material to be drawn in.  The vacuum valve will close when material covers the station’s 
volume-fill proximity sensor or this time elapses, whichever comes first. 
Vent Valve Output.  The vent valve protects the pump motor from damage during high 
vacuum conditions if an undetected failure of the vacuum switch should occur. The vent 
valve limits system vacuum by allowing a plunger in the valve to shift and vent the pump. 
Closed-Loop Conveying.  This feature allows material to be conveyed and processed 
without being contaminated by outside influences (such as dust, other materials, etc.). 
Common Purge Valve Output Control for Each Pump.  This feature allows any remaining 
material to be cleaned out of the vacuum pump or station. 
Local Blowback Filter Cleaning Outputs. When this feature is enabled, the controller 
periodically sends compressed air backward through the pump’s air filter to dislodge 
accumulated dust and debris. 
Electrical Features 
•  115/1/60 or 230/1/50/60 supply voltage 
•  24 VDC control voltage 
•  Single-point power and ground connection 
•  Non-fused disconnect switch, lockable 
•  Branch circuit fusing 
•  Fully accessible NEMA 4-style electrical control enclosure 
Controller Features 
•  Allen-Bradley SLC 5/04 programmable controller with 10” color touch screen operator 
interface  
•  Diagnostics, operating instructions and parts information are built into the interface 
•  Controls up to fifty (50) stations and up to seven (7) Vacuum Power Units. 
•  Controls up to three central alarms 
•  Allows operator to transfer stations to a standby pump when a pump fails 
•  Electronic time delay between pump startups to prevent an excessive power demand at 
your facility