Sterling 882.000254.00 Benutzerhandbuch

Seite von 91
7/50D Plus or 7/50D Controller 
Chapter 3:  Installation 
19 
10. Drive the two screws at the center points about halfway down; first on the latch side, 
then the hinge side. 
11. Continue to tighten the screws a little at a time until fully tightened; no more than 15 
inch-pounds (5.6 N
m) of torque. 
Note:  You can only pierce the cable once. Once pierced, the KwikLock 
connector must not be removed. This insures that the inner conductors 
are not exposed to the elements. 
Installing Inside KwikLink Connectors with Blank Caps 
Once installed on the grey data cables, these connectors permit you to measure voltage in the 
system so you can analyze how it is working. The system cannot work properly unless these 
inside-mounted connectors have the blank (non-conductor) caps installed. 
1.  Lay the cable in the hinged base, noting the correct keyed profile; flat edge toward 
the hinge, keyed edge toward the latch. Make sure that the cable is properly seated 
inside.
 
2.  Making sure that the cable is completely straightcarefully close the hinged 
assembly, and apply firm, even pressure until the first latch locks into place. 
Note:  Make sure that the flat cable is completely straight before continuing!! 
The latch has two catches; the first loosely holds the connector on the cable, the 
second requires more pressure to close the connector tightly. The cable must be in the 
correct position for the connector to close properly. 
3.  Drive the two screws at the center points about halfway down; first on the latch side, 
then the hinge side. 
4.  Continue to tighten the screws a little at a time until fully tightened; no more than 15 
inch-pounds (5.6 N
m) of torque. 
Note:  You can only pierce the cable once. Once pierced, the KwikLock 
connector must not be removed. This insures that the inner conductors 
are not exposed to the elements. 
The system should now be properly terminated. You can now continue to install components 
on the system. 
Figure 4:  Proper Termination Connections 
 
ArmorBlock Mounting Plate Kit
AEC P t N A0556696
Inside KwikLink Connector
with Blank Cap
Inside KwikLink Connector
with Blank Cap
 
 
 
 
Dust Caps 
Inside KwikLink Connector 
with Blank Cap 
Inside KwikLink Connector 
with Blank Cap 
ArmorBlock Mounting Plate Kit
 Part No. A0556696
Standard KwikLink
Connectors