Sterling 882.000254.00 Benutzerhandbuch

Seite von 91
7/50D Plus or 7/50D Controller 
Chapter 3:  Installation 
39 
The DeviceNet Input Status screen appears: 
 
 
Station numbers are stacked vertically as column headings in this screen. 
2.  Check that all inputs are on (green) or off (black) as expected and that they switch on 
and off as required: 
a.  Station demand switch: In a new installation, the box labeled Demand 
Switch should be green for every station (vacuum hopper) in the system. 
(All other boxes for demand switches will be black.) In a retrofit at an 
existing installation, each station’s Demand Switch box should be green 
unless the receiver bin under the station is in fact full. 
b.  Station volume-fill proximity switch: For each time-fill station, the box 
labeled Volume Fill Prox should be black; no further check is needed 
for these stations. For each volume-fill station, you should calibrate the 
sensor now and, at the same time, check this input. To calibrate the sensor, 
remove the station’s cover, extract the volume-fill proximity switch, and 
place the switch in a container of the material that you will be using at this 
station. Adjust the sensor according to the procedure given in the 
manufacturer’s documentation for the switch. While you are doing this, 
check that: 
1. 
The box on this screen is green when the sensor indicates that no 
material is present, and  
2. 
The box is black when the sensor indicates that material is 
present.  
Then reinstall the switch in the station.